What is three Intelligent Detection System for hydrogen generator?
To ensure the safe operation of the machines and to provide qualified hydrogen, the HG- series hydrogen machines are equipped with three intelligent detection systems: temperature sensing, water quality monitoring and water level detection.
• Temperature Sensor
When the temperature exceeds 60°C, the yellow light is on; when it exceeds 70°C, the red light is on, the machine alarms, the fault code E-1 is displayed, and the machine stops running at the same time.
• Water Quality Monitoring
When the TDS value exceeds 10, the red light is on, the fault code E-2 is displayed, the machine alarms, and the machine stops running at the same time.
• Water Level Detection
When there is water shortage (water level is lower than 400ml), the red light is on, the machine alarms, the fault code E-3 is displayed, and the machine stops running at the same time.
Model | HG-1000D |
Oxygen flow (ml/min) | 500 |
Hydrogen flow (ml/min) | 1000 |
Circulating water temperature (℃) | 10-60 |
Oxygen concentration (%) | 99.99 |
Hydrogen concentration (%) | 99.99 |
Source of Water | Purified or Distilled Water |
Hydrogen maximum pressure (kPa) | 100.0 |
Tank capacity (mL) | 2000.0 |
Power | AC 100-240V,50/60Hz,420W |
Dimensions (mm) | 240×240×460 |
Sewage Outlet | 2 |
Drainage method | Manual |
Net weight (kg) | 9.8 |
How can hydrogen help people's health?
That is, it has anti-oxidation and anti-free radical effects on the human body. Because hydrogen itself is a natural antioxidant, hydrogen molecules enter the human body through inhalation or drinking hydrogen water, which can neutralize excessive malignant free radicals into water and excrete them
What is SPE Electrolysis Technology ?
SPE technology, its full name is solid polymer electrolyte water electrolysis hydrogen production (oxygen) technology, using water as raw material to produce hydrogen and oxygen through proton membrane, in which hydrogen is produced at the cathode, and oxygen is produced at the anode, and the volume ratio is 2:1.
Proton membrane hydrogen production requires pure water or distilled water, and the hydrogen and oxygen produced are also of high purity.
Model | HG-2000D |
Oxygen flow (ml/min) | 1000 |
Hydrogen flow (ml/min) | 2000 |
circulating water temperature (℃) | 10-60 |
Oxygen concentration (%) | 99.99 |
Hydrogen concentration (%) | 99.99 |
Source of Water | Purified or Distilled Water |
Hydrogen maximum pressure (kPa) | 100.0 |
Tank capacity (mL) | 3000.0 |
Power | AC 100-240V,50/60Hz,690W |
Dimensions (mm) | 280×280×500 |
Sewage Outlet | 2 |
drainage method | Manual |
Net weight (kg) | 13.2 |